Low Vogetage wires & Cables

Online support

Fanpage

Featured news

Fire resistant cable 1 core, Mutiple core (FR8)

 

Liên hệ mua hàng: 024 7109 8868

100% Sản phẩm chính hãng bảo hành uy tín,

Ưu đãi trả góp Lãi suất 0% - Nhận thêm quà tặng

 

 1. 0.6/1KV PVC (FR-PVC) INSULATED (GV OR FR-GV)

0.6/1KV - CU / PVC (FR-PVC

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: GN, YL-GN, GN-YL

Packing: Roll, drum

STRUCTURE:

Conductor: Copper, class 2

Insulation: PVC (FR-PVC)

APPLCIATION: Used to connect lightning protection devices, grounding copper board... 



2 .0.6/1KV PVC INSULATED, PVC (FR-PVC) SHEATHED (VV OR FR-VV)

0.6/1KV - CU / PVC / PVC (FR-PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: PVC

Armoured: Steel wire, Steel tape

Outer Sheath: PVC (FR-PVC)

APPLICATION: Used to transmit electricity to low voltage, industrial ares, installed directly under the ground or in pipes.



3. 0.6/1KV PVC INSULATED, PVC (FR-PVC) SHEATHED (VV OR FR-VV)

0.6/1KV - CU / PVC / PVC (FR-PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: PVC

Armoured: Steel wire, Steel tape

Outer Sheath: PVC (FR-PVC)

APPLICATION: Used to transmit electricity to low voltage, industrial ares, installed directly under the ground or in pipes.


4. 0.6/1KV PVC INSULATED, PVC (FR-PVC) SHEATHED (VV OR FR-VV)

0.6/1KV - CU / PVC / PVC (FR-PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: PVC

Armoured: Steel wire, Steel tape

Outer Sheath: PVC (FR-PVC)

APPLICATION: Used to transmit electricity to low voltage, industrial ares, installed directly under the ground or in pipes.

5. 0.6/1KV XLPE INSULATED, PVC (FR-PVC) SHEATHED (CV OR FR-CV)

0.6/1KV - CU / XLPE / PVC (FR – PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: XLPE

Armoured: Aluminum wire, Aluminum tape

Outer Sheath: PVC (FR-PVC) 

6. 0.6/1KV XLPE INSULATED, PVC (FR-PVC) SHEATHED (CV OR FR-CV)

0.6/1KV - CU / XLPE / PVC (FR – PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: XLPE

Armoured: Steel wire, Steel tape

Outer Sheath: PVC (FR-PVC)

APPLICATION: Used to transmit electricity to low voltage, industrial ares, installed directly under the ground or in pipes.

7. 0.6/1KV XLPE INSULATED, PVC (FR-PVC) SHEATHED (CV OR FR-CV)

0.6/1KV - CU / XLPE / PVC (FR – PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: XLPE

Armoured: Steel wire, Steel tape

Outer Sheath: PVC (FR-PVC)

APPLICATION: Used to transmit electricity to low voltage, industrial ares, installed directly under the ground or in pipes.

8. 0.6/1KV XLPE INSULATED, PVC (FR-PVC) SHEATHED (CV OR FR-CV)

0.6/1KV - CU / XLPE / PVC (FR – PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2

Insulation: XLPE

Armoured: Steel wire, Steel tape

Outer Sheath: PVC (FR-PVC)

APPLICATION: Used to transmit electricity to low voltage, industrial ares, installed directly under the ground or in pipes. 

9.0.6/ 1KV XLPE INSULATED, PVC (FR-PVC) SHEATHED,WITH NEUTRAL CORE (CV OR FR-CV)

0.6 / 1KV – CU / XLPE / PVC (FR-PVC)

APPLIED STANDARD: IEC 60502-1 (TCVN 5935:1995)

TECHNICAL INFORMATION:

Voltage: 0.6/1kV

Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2 Insulation: XLPE

Armoured: Steel wire, Steel tape Outer Sheath: PVC (FR-PVC) 

 

10. FIRE RESISTANT CABLE 1 CORE

0.6/1KV - CU / MICA / XLPE / FR – PVC

APPLIED STANDARD: IEC 60502-1, IEC 60331

TECHNICAL INFORMATION:

Voltage: 0.6/1kV Color: BK

Packing: Roll, drum

STRUCTURE:

Conductor: Copper class 2 Tape: Mica Tape

Insulation: XLPE

Outer Sheath: FR - PVC

APPLICATION: Power transmission for the power distribution system. Used for contructions with high requirements on ‹re safety. 

11. FIRE RESISTANT CABLE MULTIPLE CORES (FR - 8)

0.6/1KV - CU / MICA / XLPE / FR – PVC

 APPLIED STANDARD: IEC 60502-1, IEC 60332

12. FIRE RESISTANT CABLE MULTIPLE CORES (FR - 3)

0.6/ 1KV - CU / XLPE / MICA / FR – PVC

 

Trusted Partner

arrow
phone 024 7109 8868